LaserHawk® 360 Installation Checklist

* Your order cannot be scheduled for production until accurate information is provided for all fields marked with an asterisk.

» Download this Document
» How to Use this Document
» LaserHawk® Technical Drawings (for reference only)


CUSTOMER CONTACT INFORMATION

Name:  *
Title:
Company:  *
Phone:  *
FAX:
Email:  *
Stack Identification:  *

2. MOUTING FLANGE ( Select One of the following)  *
I will supply my own 4 inch flanges for the Standard Installation
I wish to use something other than 4 inch flanges, described below:


3. MOUNTING TUBE LENGTH  *
The typical length of the mounting tube is between 2 inches and 8 inches in length including the flanges and adapters. If the process to be measured is 500°F or above, we recommend using a Mounting Tube Length of 6 inches.  Let us know the length in one of the following units.
Inches Centimeters
4. Stack or Duct Dimension at Installation Port Location:   
Small diameter stacks may require an optional LIGHT TRAP, which is a device that prevents laser energy reflecting off the far stack wall opposite the Optical Head from being reflected into the viewing optics. A LIGHT TRAP is generally required only for stack diameters less than 6.5 feet (2 meters), but may be necessary at great diameters based on mounting tube length, particulate mass range and other factors.
Feet Meters




5. TEMPERATURE OF PROCESS     
Typical: F C
Maximum Less than 500 deg F(260C)
501 to 1500 deg F (261 to 815C)
>1500F(815C) Consult Factory
6. PROCESS PRESSURE  * (SELECT ONE OF THE FOLLOWING)    

-15.0 to 5.0inches H2O (-3.745 to +1.245 kilopascal)
Other, Consult Factory


7. MOUNTING CLEARANCE (SELECT ONE OF THE FOLLOWING)

The standard Mounting Clearance is sufficient.
I will use something other than the standard Mounting Clearance, described below:
 

8. DATA CABLE LENGTH (The data cable is supplied at an additionalcost.)

I wish to purchase:

Feet of Data Cable

9. STACK POWER CIRCUIT REQUIRMENTS
Optical Head: 85-245 VAC, 47-63Hertz, Single Phase, 30 VA Maximum
Purge Blower: 115/230 VAC, Single Phase, 414 VA Maximum
Number (#): Does not apply to instrument Air Purge Version


10. CORRECTION TO STANDARD CONDITION  *

Some sites may wish to correct the Particulate measurement to Standard Conditions by measuring the process temperature and pressure. The LaserHawk® 360 can mathematically correct for temperature and pressure if they are supplied as inputs to the monitor. If you want this option, let us know where you want to locate the input module:
I do NOT want this option ( Skip to Section 11)
I do want this option ( Please complete Section s 10.1, 10.2 & 10.3)
 
10.1 LOCATION OF THE DUAL ANALOG INPUT MODULE
At the Stack or Duct Location
In the Control Room


10.2 BAROMETRIC PRESSURE TRANSDUCER OPTIONS
Measurement Location on Stack (above mean sea level) Feet Meters
Control Room Location (above mean sea level) Feet Meters


10.2.2 BAROMETRIC PRESSURE TRANSDUCER OPTIONS
I do NOT want to use any Barometric Pressure Transducer 

I do want to use the Barometric Pressure Transducer and I wish to purchase the Pressure Sensor from Teledyne Monitor Labs.      

I DO want to use the Barometric Pressure Transducer and I will supply my own  

See scaling below

 

Type Scaling
  Value @ 1V or 4mA Value @ 5V or 20mA
Voltage
Current

10.3 EXTERNAL TEMPERATURE OPTIONS
I do NOT want to use the External Temperature Option. 

I DO want to use the External Temperature Option and I wish to purchase a temperature sensor from Teledyne Monitor Labs, Inc.

I DO want to use the External Temperature Option and I will supply my own.

(See scaling below).


Type

Scaling

  Value @ 1V or 4mA Value @ 5V or 20mA
Voltage
Current
1000 ohm RTD    
100 ohm RTD    


11. MAXIMUM PARTICULATE LIMIT  *
Emission Limit Units


12. FULL SCALE DETERMINATION  *
In order to properly set the sensitivity and full scale of the LaserHawk 360 we need to know some details about the process to be measured. If the process includes a particulate control device, what type is it? If so, will the monitor be located before or after the control device?

What measurement units are desired? Typical units are: mg/Am³, mg/Nm³, grains/Aft³, grains/Nft³, grains/DRY Sft³, lbs/mmbtu.

Note: "A" is for actual or uncorrected while "N" is for normalized or corrected for temperature and pressure.
Particulate Control Device (NONE, ESP,Baghouse, etc.)
Monitor will be located BEFORE or AFTER control device No Control Device    Before Device    After Device
Typical Barometric Pressure  Units in. Hg   mm Hg
Requested Full Scale  Units
If the requested full Scale units are lbs/mmbtu or in DRY units please complete the following:
Fuel Type or Fuel Constant
Typical CO2
Specify if CO2 is Wet or Dry
Typical Moisture %


13. USE AUTO CAL SEQUENCE? (SELECT ONE OF THE FOLLOWING)


YES
NO


14. SYSTEM CONFIGURATION  * (SELECT ONE OF THE FOLLOWING)
Direct Interface
Enhanced Remote Panel


If you selected the Direct Interface Configuration, fill out the following:
Output Units: Opacity Optical Density Particulate Mass, Consult Factory
Current Outputs: 4 to 20 milliamp 0 to 20 milliamp
Relay Output #1:
Relay Output #2:
Digital Input #1:
Digital Input #2:


Only if you selected the Enhanced Remote Panel Configuration, fill out this page:
Analog Output #1:
Analog Output #2:
Analog Output #3:
Analog Output #4:

Relay K1:
Relay K2:
Relay K3:
Relay K4:
Relay K5:
Relay K6:
Relay K7:
Relay K8:


Ethernet Module Setup
Use a Dynamic Internet Provider (IP) address
Use a Static Internet Provider (IP)>address, if yes please supply the information below:
Static IP Address  
Subnet Mask  
Default Gateway


Enhanced Remote Panel Power Circuit Requirements:
85-245 Volts Alternating Current, 47-63 Hertz, Single Phase, 30 Volts Alternating Current Maximum
115 Volts Alternating Current Power Cord 230 Volts Alternating Current Power Cord

Enter code to confirm submission
Confirmation:   Validation Enter Confirmation Code:   *
 
 





Home | Warranty | Terms of Use | Service & Support | Products | Contact Us

Copyright © 2009 Teledyne Technologies Incorporated. All rights reserved.
35 Inverness Drive East - Englewood, CO 80112